Sound Solutions for Habitable to Wet Cases

The sound solutions given in this section are only applicable to Austral Bricks NSW products. Bricks that are made using different manufacture techniques and raw materials will have different levels of acoustic performance.

CONSTRUCTION: Habitable to Wet
REQUIREMENTS: Rw + Ctr > 50
With discontinuous construction.

Walls separating a habitable room in one dwelling from a wet room in a second dwelling are required to have an Rw+Ctr of not less than 50 and to have a discontinuous construction. A wet room is a kitchen, bathroom, sanitary compartment or laundry. Discontinuous construction requires:

  • A minimum 20mm cavity between two separate leaves
  • Resilient wall ties such as those provided by Matrix Industries, if the wall is masonry, and
  • No mechanical linkage if the leaves are not masonry.

The description given above is an aid only and the BCA should be referred to for the full requirements. Sound Solutions for this case are given below for:

  • 110mm Standard Series
  • Dry Press Series
  • 90mm Maxi Series
  • 150mm Through Wall Series

Test certificates are available on request. Sound or acoustic performance is measured by the weighted sound reduction index (Rw). The Rw value will increase as the acoustic performance of a material or construction improves. For further information on acoustic performance and the requirements of the building code, refer to either:

110mm (Standard Series) Sound Solutions*
 Send Side:
13mm plasterboard directly fixed
Receive Side:
13mm plasterboard screw fixed to 70mm x 35mm timber studs 20mm from wall, with insulation

Discontinuous Construction:  Yes
Wall Thickness: 226mm

Rw + Ctr ≥ 50
BCA Deemed
to Comply
Send Side:
13mm 'SoundStop' plasterboard screw fixed to furring channels, with insulation
Receive Side:
13mm 'SoundStop' plasterboard screw fixed to 51mm steel studs 20mm from wall, with insulation

Discontinuous Construction:
Yes
Wall Thickness: 228mm

Rw 60 (-3;-10)
Rw = 60
Rw + Ctr = 50

ATF Report 1749
Send Side:
13mm plasterboard directly fixed
Receive Side:
13mm plasterboard screw fixed to 64mm steel stud 15mm from wall, with insulation

Discontinuous Construction:  Yes
Wall Thickness: 215mm
 
Rw 62 (-3;-9)
Rw = 62
Rw + Ctr = 53

ATF Report 1125  
Send Side:
10mm plasterboard screw fixed to 70mm x 30mm timber studs 15mm from wall, with insulation
Receive Side:
10mm plasterboard screw fixed to 70mm x 30mm timber studs 15mm from wall, with insulation

Discontinuous Construction: Yes
Wall Thickness: 300mm

Rw 65 (-6;-14)
Rw = 65
Rw + Ctr = 51


ATF Report 1398
Send Side:
13mm 'SoundStop' plasterboard screw fixed to furring channels, with insulation
Receive Side:
13mm 'SoundStop' plasterboard and 10mm plasterboard screw fixed to 51mm steel studs 20mm from wall, with insulation

Discontinuous Construction:  Yes
Wall Thickness: 238mm

Rw 65 (-4;-12)
Rw = 65
Rw + Ctr = 53


ATF Report 1750
  Send Side:
13mm plasterboard screw fixed to 64mm steel stud 15mm from wall, with insulation
Receive Side:
13mm plasterboard screw fixed to 64mm steel stud 15mm from wall, with insulation

Discontinuous Construction: Yes
Wall Thickness: 294mm

Rw 70 (-5;-13)
Rw = 70
Rw + Ctr = 57


ATF Report 1123
50mm cavity, with insulation

Send Side:
No finish
Receive Side:
No finish

Discontinuous Construction: Yes
Wall Thickness: 270mm
 
Rw + Ctr ≥ 50
BCA Deemed
to Comply
  50mm cavity

Send Side:
13mm render coating
Receive Side:
13mm render coating

Discontinuous Construction: Yes
Wall Thickness: 296mm
 
Rw + Ctr ≥ 50
BCA Deemed
to Comply

*These acoustic results should be used in conjunction with the specific details given in the test certificates or BCA deemed-to-satisfy descriptions.

Dry Press Sound Solutions*
Send Side:
13mm plasterboard directly fixed
Receive Side:
13mm plasterboard screw fixed to 70mm x 30mm timber studs at 600mm centres, 20mm from wall, with insulation

Discontinuous Construction: Yes
Wall Thickness: 226mm
 

Rw + Ctr ≥ 50
BCA Deemed to Comply

 Send Side:
13mm plasterboard directly fixed
Receive Side:
13mm plasterboard screw fixed to 64mm steel stud at 600mm centres, 20mm from wall, with insulation

Discontinuous Construction: Yes
Wall Thickness: 220mm
 

Rw + Ctr ≥ 50
BCA Deemed to Comply

50mm cavity

Send Side:
No finish
Receive Side:
No finish

Discontinuous Construction:  Yes
Wall Thickness: 270mm

Rw 53 (-1;-3)
Rw = 53
Rw + Ctr = 50


ATF Report 1174
50mm cavity, with insulation

Send Side:
No finish
Receive Side:
No finish

Discontinuous Construction: Yes
Wall Thickness: 270mm
 

Rw + Ctr ≥ 50
BCA Deemed to Comply

                                            40mm Cavity

Send Side:

10mm plasterboard directly fixed
Receive Side:
10mm plasterboard directly fixed

Discontinuous Construction: Yes
Wall Thickness: 280 mm

Rw 54 (-1;-4)
Rw = 54
Rw + Ctr = 50


ATF Report 1463A
50mm cavity

Send Side:
13mm render
Receive Side:
13mm render

Discontinuous Construction: Yes
Wall Thickness: 296mm
 
Rw 55 (-1;-4)
Rw = 55
Rw + Ctr = 51


ATF Report 1175

*These acoustic results should be used in conjunction with the specific details given in the test certificates or BCA deemed-to-satisfy descriptions.

90mm (Maxi Series) Sound Solutions*
Send Side:
Plasterboard directly fixed to 70mm x 35mm timber studs at 600mm centres 20mm from wall, with insulation
Receive Side:
Plasterboard directly fixed to 70mm x 35mm timber studs at 600mm centres 20mm from wall, with insulation

Discontinuous Construction: Yes
Wall Thickness: 296mm
 
Rw + Ctr ≥ 50
BCA Deemed
to Comply

Send Side:
13mm plasterboard screw fixed to 64mm steel stud 15mm from wall, with insulation
Receive Side:
13mm plasterboard screw fixed to 64mm steel stud 15mm from wall, with insulation

Discontinuous Construction: Yes
Wall Thickness: 274mm
 
Rw 65 (-7;-14)
Rw = 65
Rw + Ctr = 51


ATF Report 1131

*These acoustic results should be used in conjunction with the specific details given in the test certificates or BCA deemed-to-satisfy descriptions.

150mm (through Wall Series) Sound Solutions*
             
Send Side:
13mm plasterboard directly fixed
Receive Side:
13mm plasterboard fixed to 64mm steel studs 15mm from wall, with insulation

Discontinuous Construction: Yes
Wall Thickness: 255mm
 
Rw 60 (-2;-8)
Rw = 60
Rw + Ctr = 51


ATF Report 1115